OVERLOAD SAFETY DEVICES

Overload safety devices provide protection against accidental overloading for hoistings of any kind.

Overload Protection Device
Typ: R-0311

Properties
  • Input: 1× strain gauge bridge
  • Power supply: 230 V AC (50/60 Hz)
    • Option: 24 V DC (20…30 V DC)
    • Option: 110 V AC (50/60 Hz)
  • Connection: EMC cable gland, screw terminals
  • Contacts: 1× relay (SPDT)
  • Functions: overload, slack rope
  • Ingress protection (IEC/EN 60529): IP 65
  • Material: die-cast aluminium
  • Dimensions: 125×80×54 mm
  • Operating temperature: −25…+70 °C
    • Option: −40…+80 °C
Options
  • ATEX certification
Highlights
  • Low-cost solution for simple overload protection
  • Easily adjustable without requiring special tools

Overload Protection Device
Type: R-0312

Properties
  • Input: 1× strain gauge bridge
  • Power supply: 230 V AC (50/60 Hz)
    • Option: 24 V DC (20…30 V DC)
    • Option: 110 V AC (50/60 Hz)
  • Connection: EMC cable gland, screw terminals
  • Contacts: 2× relay (SPDT)
  • Functions: overload, slack rope
  • Ingress protection (IEC/EN 60529): IP 65
  • Material: die-cast aluminium
  • Dimensions: 175×80×54 mm
  • Operating temperature: −25…+70 °C
    • Option: −40…+80 °C
Options
  • ATEX certification
Highlights
  • Two relay contacts
  • Easily adjustable without requiring special tools

Overload Protection Device with current loop output
Type: R-0313

Properties
  • Input: 1× strain gauge bridge
  • Power supply: 230 V AC (50/60 Hz)
    • Option: 24 V DC (20…30 V DC)
    • Option: 110 V AC (50/60 Hz)
  • Connection: EMC cable gland, screw terminals
  • Output: current loop (4…20 mA)
  • Contacts: 1× relay (SPDT)
  • Functions: overload, slack rope
  • Ingress protection (IEC/EN 60529): IP 65
  • Material: die-cast aluminium
  • Dimensions: 175×80×54 mm
  • Operating temperature: −25…+70 °C
    • Option: −40…+80 °C
Options
  • ATEX certification
Highlights
  • Overload protection with current loop output
  • Ideally suited for conversion of strain gauge bridge sensors to current loop signalling (e.g. for PLCs)
  • Easily adjustable without special tools

Overload Protection Device with current loop output
Type: R-0316

Properties
  • Inputs: 1× strain gauge bridge, 1× current loop (4…20 mA)
  • Power supply: 230 V AC (50/60 Hz)
    • Option: 24 V DC (20…30 V DC)
    • Option: 110 V AC (50/60 Hz)
  • Connection: EMC cable gland, screw terminals
  • Output: 1× current loop (4…20 mA)
  • Contacts: 2× relay (SPDT)
  • Functions: overload, slack rope
  • Ingress protection (IEC/EN 60529): IP 65
  • Material: die-cast aluminium
  • Dimensions: 220×120×80 mm
  • Operating temperature: −25…+70 °C
    • Option: −40…+80 °C
Options
  • ATEX certification
Highlights
  • Ideally suited for conversion of strain gauge bridge sensors to current loop signalling (e.g. for PLCs)
  • Easily adjustable without special tools
  • Additional current input
  • Load summation

Digital Overload Protection Device
Type: MVD-0485

Properties
  • Inputs: 1…4× current loop (4…20 mA)
  • Power supply: 110…230 V AC (50/60 Hz)
    • Option: 24 V DC (20…30 V DC)
  • Connection: EMC cable gland, spring-loaded terminals
  • Outputs: 0…4× current loop (4…20 mA)
  • Contacts: 6× safety relay (normally open, supervised)
    • Option: 14× safety relay (normally open, supervised)
    • Option: 22× safety relay (normally open, supervised)
    • Option: 6/14/22× safety relay (SPDT, supervised)
  • Functions: overload, slack rope, cross comparison, etc.
  • Ingress protection (IEC/EN 60529): IP 65
  • Material: die-cast aluminium
  • Dimensions: 230×200×111 mm
    • Option: 330×230×111 mm (for 22× relay options)
  • Operating temperature: −25…+70 °C
    • Option: −40…+80 °C
Options
  • ATEX certification
Highlights
  • Load spectrum recorder (in accordance to FEM 9.755)
  • Serial interface (RS-485)
  • Digital inputs
  • Configuration on device or with the comfortable PC companion software (via RS-232)

Configurable Logic Controller
Typ: SKS-0586

Properties
  • Inputs: 1…4× current loop (4…20 mA)
  • Power supply: 110…230 V AC (50/60 Hz)
    • Option: 24 V DC (20…30 V DC)
  • Connection: EMC cable gland, spring-loaded terminals
  • Outputs: 0…4× current loop (4…20 mA)
  • Contacts: 6× safety relay (normally open, supervised)
    • Option: 14× safety relay (normally open, supervised)
    • Option: 22× safety relay (normally open, supervised)
    • Option: 6/14/22× safety relay (SPDT, supervised)
  • Functions: overload, slack rope, cross comparison, etc.
  • Ingress protection (IEC/EN 60529): IP 65
  • Material: die-cast aluminium
  • Dimensions: 230×200×111 mm
    • Option: 330×230×111 mm (for 22× relay options)
  • Operating temperature: −25…+70 °C
    • Option: −40…+80 °C
Options
  • ATEX certification
Highlights
  • Load spectrum recorder (in accordance to FEM 9.755)
  • Serial interface (RS-485)
  • Digital inputs
  • Jib radius calculation
  • Load curve
  • Configuration on device or with the comfortable PC companion software (via RS-232)