LOAD SPECTRUM COUNTERS

Digital Overload Protection Device with Load Spectrum Counter
Type: MVD-0485

Properties
  • Inputs: 1…4× current loop (4…20 mA)
  • Power supply: 110…230 V AC (50/60 Hz)
    • Option: 24 V DC (20…30 V DC)
  • Connection: EMC cable gland, spring-loaded terminals
  • Outputs: 0…4× current loop (4…20 mA)
  • Contacts: 6× safety relay (normally open, supervised)
    • Option: 14× safety relay (normally open, supervised)
    • Option: 22× safety relay (normally open, supervised)
    • Option: 6/14/22× safety relay (SPDT, supervised)
  • Functions: overload, slack rope, cross comparison, etc.
  • Ingress protection (IEC/EN 60529): IP 65
  • Material: die-cast aluminium
  • Dimensions: 230×200×111 mm
    • Option: 330×230×111 mm (for 22× relay options)
  • Operating temperature: −25…+70 °C
    • Option: −40…+80 °C

Configurable Logic Controller with Load Spectrum Counter
Typ: SKS-0586

Properties
  • Inputs: 1…4× current loop (4…20 mA)
  • Power supply: 110…230 V AC (50/60 Hz)
    • Option: 24 V DC (20…30 V DC)
  • Connection: EMC cable gland, spring-loaded terminals
  • Outputs: 0…4× current loop (4…20 mA)
  • Contacts: 6× safety relay (normally open, supervised)
    • Option: 14× safety relay (normally open, supervised)
    • Option: 22× safety relay (normally open, supervised)
    • Option: 6/14/22× safety relay (SPDT, supervised)
  • Functions: overload, slack rope, cross comparison, etc.
  • Ingress protection (IEC/EN 60529): IP 65
  • Material: die-cast aluminium
  • Dimensions: 230×200×111 mm
    • Option: 330×230×111 mm (for 22× relay options)
  • Operating temperature: −25…+70 °C
    • Option: −40…+80 °C